If you are renovating a bathroom or building a new home in Victoria, the rules for wet area waterproofing come from two sources. The National Construction Code (NCC) sets what the building must achieve. AS 3740:2021, Waterproofing of domestic wet areas, is the standard the NCC refers to for wet area construction. NCC 2025 is the edition adopted in Victoria from 1 May 2026, according to the National Construction Code 2025 edition page.
What the free NCC text says
Part 10.2 of the NCC Housing Provisions, Wet area waterproofing, is free to read. It refers to AS 3740 for wet area construction, and it sets several heights and a fall that are worth checking against any quote:
- Shower walls: waterproofed to at least 1800 mm above the floor where the shower has a hob, step-down or level threshold.
- Walls beside a bath or other vessel: where the vessel sits within 75 mm of the wall, the wall is water resistant to at least 150 mm above the vessel.
- Floor waste: where a floor waste is installed, the minimum continuous fall to the waste is 1:80.
AS 3740 is a paywalled standard, so this guide does not quote it. For details the free text does not give, such as hob construction, bond breaker methods or how penetrations are sealed, check the standard itself or ask your waterproofer how they meet it.
Why the detail matters
Wet area failures usually start at the edges of the room: the junction between the shower floor and wall, the hob, the waste outlet, the penetrations for taps and fittings, and the internal corners. The heights above show where the membrane must run. The standard governs how each junction is built, so these are the points to ask a waterproofer to show you before tiles go down.
Compliance and paperwork in Victoria
Building work in Victoria has to meet the NCC as adopted in the state. Ask your builder what compliance paperwork will be provided for the waterproofing, and who will sign it.
An insurer may refuse a claim for damage linked to building work that did not comply with the law. Read your policy and ask your insurer before the job starts.
Water that reaches timber framing can cause rot. Repairing a failed wet area usually means removing finished tiles and checking the structure underneath, which is costly.
Consumer Affairs Victoria covers building and renovating, including owner-builder arrangements.
Choosing a waterproofer
Ask who will do the work, check their registration with the Building and Plumbing Commission (formerly the Victorian Building Authority) for the work being done, and ask what written evidence of the waterproofing you will receive. If you want the wet area detailed against the NCC and AS 3740 before tiling, see wet area waterproofing and independent waterproofing inspections. The NCC guide explains how the code fits together.
Services
Related services
The services that cover the work in this guide.
- Wet area waterproofingBathrooms, laundries and toilets waterproofed at the falls, junctions and waste outlets that decide whether a wet area holds water.
- Screed shower bases and balconiesScreed shower bases and balcony screeds built with the falls, membrane and waste detail that keep water in the drain.
- Independent waterproofing inspectionsIndependent inspections of waterproofing before it is covered, or of existing work that is in question.
Guides
Related guides
Longer reading on the membranes, details and standards behind this work.
- What an Independent Waterproofing Inspection Checks in VictoriaWhat an independent waterproofing inspection checks before tiling in Victoria: the membrane, junctions, falls, wall heights and the flood test.
- Common Balcony Waterproofing Failures in Melbourne (And How to Prevent Them)Why balconies leak in Melbourne: ponding water, the wrong membrane, failed junctions and efflorescence, and what to check before tiling.
- Understanding Waterproofing Membranes: A Guide for HomeownersThe main membrane types for homes, liquid-applied and sheet, where each one suits, and why surface preparation decides how well either performs.