Guide
Navigating the National Construction Code (NCC) for Waterproofing
How NCC 2025, the Housing Provisions and AS 3740 fit together for waterproofing wet areas in Victoria, with the wet area heights and floor waste fall.
2 min readUpdated
The National Construction Code (NCC) sets the minimum requirements for safety, health, amenity and sustainability in Australian buildings. NCC 2025 is the edition adopted in Victoria from 1 May 2026, according to the National Construction Code 2025 edition page. Some requirements vary between states and territories, so check the Victorian position as well as the national text.
How the rules fit together
- The NCC and its Housing Provisions. The Housing Provisions set out the requirements for houses and related buildings. Part 10.2 covers wet areas.
- Part 10.2 refers to AS 3740. The wet area construction clauses refer to AS 3740:2021, Waterproofing of domestic wet areas, a paywalled standard.
- The job paperwork. The specification, the membrane maker's instructions and the compliance documents show what will actually be built.
Wet area heights and falls in the free text
Part 10.2 of the NCC 2025 Housing Provisions sets these figures, and the text is free to read (Part 10.2):
- Shower walls waterproofed to at least 1800 mm above the floor where the shower has a hob, step-down or level threshold.
- Walls beside a bath or other vessel, where the vessel sits within 75 mm of the wall, water resistant to at least 150 mm above the vessel.
- Where a floor waste is installed, a minimum continuous fall of 1:80 to the waste.
This guide does not cover other wet area requirements, such as those for timber or concrete floors. Check Part 10.2 and AS 3740 for those.
Compliance and insurance
In Victoria, building work must meet the NCC as adopted in the state, so the paperwork for the waterproofing should show how it does. An insurer may refuse a claim for damage linked to work that did not comply, so check your policy. Consumer Affairs Victoria covers planning and managing a building project.
Working with a waterproofer
When you choose a waterproofer, ask how they will show the work meets the NCC and AS 3740, and check their registration with the Building and Plumbing Commission (formerly the Victorian Building Authority). Wet area waterproofing and waterproofing inspections describe the work we do in these areas. Contact us to talk about your project.
Services
Related services
The services that cover the work in this guide.
- Retaining wall waterproofingRetaining and below-ground walls waterproofed with a membrane and a drainage path that takes soil water away before it builds up.
- External waterproofingAbove-ground external surfaces waterproofed so water drains away from the structure and the walls it meets.
- Independent waterproofing inspectionsIndependent inspections of waterproofing before it is covered, or of existing work that is in question.
Guides
Related guides
Longer reading on the membranes, details and standards behind this work.
- The Dangers of DIY Waterproofing in VictoriaThinking of waterproofing a bathroom yourself in Victoria? Check the permit, registration and insurance rules before you start, and get advice first.
- Understanding Polyurethane vs. Acrylic MembranesPolyurethane or acrylic membrane? How the two compare on movement, UV exposure and standing water, and how to check a product's data sheet.
- Waterproofing Terminations and Hobs: Getting the Details RightWhere waterproofing must end at doorways, hobs and walls in a bathroom, with the minimum shower and bath wall heights from the NCC Housing Provisions.